AC Serial Spindle Unit Alarms

Fanuc AC Serial Spindle Alarms and Error Codes.

These Alarm and Error Codes cover A06B-6062, A06B-6063, A06B-6064.

Please contact us if you need testing, a repair or an exchange part. For further information please visit our dedicated Fanuc AC Serial Spindle Page.

Alarm Code Type
Description of Alarm/ Faults
A display Program ROM abnormality Detects that control program is not started ( due to program ROM not installed)
01 Motor Overheat Detects internal motor temperature exceeding specified temperature.
02 Excessive Speed deviation Detects motor speed exceeding specified speed excessively.
03 DC Link section fuse blown Detects that fuse F4 in DC link section is blown ( models 30S and 40S).
04 Input fuse blown

Input power open phase

Detects blown fuse (F1 to F3), open phase or momentary failure of power (models 30S and 40S)
05 Control Power Supply Fuse Blown Detects that control power supply fuse AF2 or AF3 is blown (models 30S and 40S)
07 Excessive Speed Detects that motor rotation has exceeded 115% of its rated speed.
08 High input voltage Detects that the switch us flipped to 200 VAC when input voltage is 230 VAC or higher. (models 30S and 40S)
09 Excessive load on main circuit section Detects abnormal temperature rise of power transistor radiator.
10 Low input voltage Detects drop in input power supply voltage.
11 Over-voltage in DC link section Detects abnormally high direct current power supply voltage in power circuit section.
12 Over current in DC link Section Detects flow of abnormally large current in direct current section of power circuit.
13 CPU internal data memory abnormality Detects abnormality in CPU internal data memory. This check is made only when the power is turned on.
15 Spindle switch/output switch alarm Detects incorrect switch sequence in spindle switch/output switch operation.
16 RAM abnormality Detects abnormality in RAM for external data. This check is made only when power is turned on.
18 Program ROM sum check error Detects program ROM data error. This check is made only when the power is turned on.
19 Excessive U Phase current detection circuit offset Detects excessive U phase current detection circuit offset. This check is made only when the power is turned on.
20 Excessive U Phase current detection circuit offset Detects excessive V phase current detection circuit offset. This check is made only when the power is turned on.
24 Serial transfer data error Detects serial transfer error (such as NC power supplied turned off).
25 Serial data transfer stopped Detects that serial data transfer has stopped.
26 Disconnection of speed detection signal for Cs contouring control Detects abnormality in position coder signal (such as unconnected cable and parameter setting error).
27 Position coder signal disconnection Detects abnormality in position coder signal ( such as unconnected cable and parameter setting error).
28 Disconnection of position detection signal for Cs contouring control Detects abnormality in position detection signal for Cs contouring control ( such as unconnected cable and adjustment error)
29 Short time overload Detects that overload has been continuously applied for some period of time.
30 Input circuit overcurrent Detects overcurrent flowing in input circuit.
31 Speed detection signal disconnection motor restraint alarm Detects that the motor cannot rotate at the specified speed( but rotates at very slow speed or has stopped) (This includes checking of speed detection signal cable)
32 Abnormality in RAM internal to LSI for serial data transfer Detects abnormality in RAM internal to LSI for serial data transfer. This check is made only when the power is turned on.
33 Insufficient DC link section charging Detects insufficient charging of direct current power supply voltage in power circuit section when magnetic contactor in amplifier is turned on.
34 Parameter data setting beyond allowable range of values Detects parameter data set beyond allowable range of values
35 Excessive gear ratio data setting Detects gear ratio data set beyond allowable range of values
36 Error counter overflow Detects error counter overflow
37 Speed detector parameter setting error Detects incorrect setting of parameter for number of speed detection pulses
39 Alarm for indicating failure in detecting 1 rotation signal for Cs contouring control Detects 1 rotation signal detection failure in Cs contouring control
40 Alarm for indicating 1 rotation signal for Cs contouring control not detected Detects that 1 rotation signal has not occurred in Cs contouring control
41 Alarm for indicating failure in detecting position coder 1 rotation signal Detects failure in detecting position coder 1 rotation signal
42 Alarm for indicating position coder 1 rotation signal not detected Detects that position coder 1 rotation signal has not occurred
43 Alarm for indicating disconnection of position coder signal for differential speed mode Detects that the main spindle position coder signal used for differential speed mode is not connected yet ( or is disconnected)
46 Alarm for indicating failure in detecting position coder 1-rotation signal in thread cutting operation Detects failure in detecting position coder 1 rotation signal in thread cutting operation
47 Position coder signal abnormality Detects incorrect position coder signal count operation
48 Position coder 1 rotation signal abnormality Detects that occurrence of position coder 1 rotation signal has stopped
49 The converted differential speed is too high Detects that speed of other spindle converted to speed of local spindle has exceeded allowable limit in differential mode.
50 Excessive speed command calculation value in spindle synchronization control  Detects that speed command calculation value exceeded allowable range in spindle synchronization control.
51 Under-voltage at DC link section Detects that DC power supply voltage of power circuit has dropped.
52 ITP signal abnormality I Detects abnormality in synchronization signal (ITP signal) with CNC.
53 ITP signal abnormality II Detects abnormality in synchronization signal (ITP signal) with CNC.
54 Overload current alarm Detects that excessive current flowed in motor for long time.
55 Power line abnormality in spindle switching/output switching Detects that switch request signal does not match power line status check signal.