FANUC BETA iSV Alarms
Fanuc Beta I Servo Unit Alarms and Error Codes.
These Fanuc Beta I Servo Unit Alarms relate to the A06B-6130 & A06B-6132 Series. Please contact us if you need testing, a repair or an exchange part. For further information please visit our dedicated Fanuc Beta I Servo Unit Page.
Servo Amplifier Module Alarms
Alarm Code | LED |
Description of Alarm/Error |
Converter: DC link undervoltage | ON | Voltage drop at the DC link in the main circuit. |
Converter: DC link overvoltage | ON | Voltage rise at the DC link in the main circuit. |
Converter: Excessive deceleration power | ON | Too large or abnormal regenerative discharge amount. |
Converter: Control power supply undervoltage | ON |
|
Inverter: Internal cooling fan stopped | ON |
|
Inverter: Internal cooling fan stopped of the radiator | ON |
|
Inverter: IPM alarm | ON |
|
Inverter: IPM alarm (OH) | ON |
|
Inverter: Motor current alarm | ON |
|
Inverter: FSSB communication error | ON |
|
Servo Alarm For Series 15i
Alarm Code | Description |
SV0027 | Invalid digital servo parameter setting |
SV0361 | Pulsecoder phase error ( built in) |
SV0364 | Soft phase alarm (built in) |
SV0365 | LED error ( built in) |
SV0366 | Pulse error (built in) |
SV0367 | Count error (built in) |
SV0368 | Serial data error (built in) |
SV0369 | Data transfer error ( built in) |
SV0380 | LED error ( separate) |
SV0381 | Pulsecoder phase error (separate) |
SV0382 | Count error ( separate) |
SV0383 | Pulse error (separate) |
SV0384 | Soft phase alarm (separate) |
SV0385 | Serial data error (separate) |
SV0386 | Data transfer error (separate) |
SV0387 | Sensor error(separate) |
SV0421 | Excessive semi full error |
SV0430 | Servo motor overheat |
SV0432 | Converter: control power supply undervoltage
|
SV0433 | Converter: DC Link undervoltage |
SV0436 | Soft thermal (OVC) |
SV0438 | Inverter: motor current alarm |
SV0439 | Converter: DC link overvoltage |
SV0440 | Converter: Excessive deceleration power |
SV0441 | Current offset error |
SV0444 | Inverter: internal cooling fan stopped |
SV0445 | Soft disconnection alarm |
SV0447 | Hard disconnection alarm (separate) |
SV0448 | Feedback mismatch alarm |
SV0449 | Inverter: IPM alarm |
SV0601 | Inverter: cooling fan stopped of the radiator |
SV0603 | Inverter: IPM alarm (OH) |
Servo Alarm For Series 16i, 18i, 20i, 21i, 0i and Power Mate i.
Alarm Code | Description |
361 | Pulsecoder phase error ( built in) |
364 | Soft phase alarm ( built in) |
365 | LED error ( built in) |
366 | Pulse error (built in) |
367 | Count error (built in) |
368 | Serial data error (built in) |
369 | Data transfer error ( built in) |
380 | LED error (separate) |
381 | Pulsecoder phase error ( separate) |
382 | Count error ( separate) |
383 | Pulse error ( separate) |
384 | Soft phase alarm (separate) |
385 | Serial data error ( separate) |
386 | Data transfer error (separate) |
387 | Sensor error (separate) |
417 | Invalid parameter |
421 | Excessive semi full error |
430 | Servo motor overheat |
432 | Converter: Control undervoltage |
433 | Converter: DC link undervoltage |
436 | Soft thermal (OVC) |
438 | Inverter: motor current alarm |
439 | Converter: DC link overvoltage |
440 | Converter: excessive deceleration power |
441 | Current offset error |
444 | Inverter: internal cooling fan stopped |
445 | Soft disconnection alarm |
447 | Hard disconnection alarm (a Pulsecoder) |
448 | Feedback mismatch alarm |
449 | Inverter : IPM alarm |
453 | Soft disconnection alarm ( a Pulsecoder) |
601 | Inverter: cooling fan stopped of the radiator |
603 | Inverter: IPM alarm (OH) |